MQTT is the primary path. LoRaWAN lands through a network server. Modbus lands through an industrial gateway.
Introduction
What this covers
Which protocols Factora accepts directly, and which ones stop at a gateway that then publishes a numeric MQTT value.
Why it matters on the floor
Pointing a PLC at the MQTT port, or treating a LoRaWAN regional plan as a Factora setting, leaves the line dark on commissioning day.
By the end you can
Name the HTTP ingest path and the MQTT topic, username, and password
Place LoRaWAN, cellular, Modbus, OPC-UA, and Bluetooth location on the correct side of the gateway
Write a minimum payload and explain that regional radio plans belong on the gateway, not in Factora
About 22 minutes. Prerequisites: Architecture, so the ingest pipeline is already clear.
Protocol map
Protocol
Where it runs
How it enters Factora
HTTP ingest
POST /api/ingest
Direct
MQTT
mqtt://iot.factoraerp.com:1883
Direct, topic ACL
LoRaWAN
Certified LoRaWAN gateway and network server
Decode → MQTT JSON value
Cellular
Industrial 4G/LTE gateway
MQTT publisher or MQTT-Modbus gateway
Modbus RTU/TCP
Meter/PLC
Industrial gateway → numeric MQTT
OPC-UA
Plant server
Not a bundled driver; gateway → MQTT
BLE AoA / UWB RTLS
Location anchors and tags
Location events → custom HTTP/MQTT map
Simulator
Demo plants
Internal, labeled DEMO
Factora MQTT username is the device code; password is the ingest token. Topic:
factora/{slug}/devices/{code}/telemetry
Payload minimum: {"value": 9.4}. Optional messageId for idempotency.
LoRaWAN regional plans (EU868, US915, IN865, AS923, CN470, …) are gateway settings, not Factora settings. Hardware is multi-vendor (LoRaWAN, Modbus, 4G/LTE). No brand is assumed.