Knowledge Hub

Factora Academy

Knowledge Hub · Courses · IoT.Factora · Technology · 25 min

Sensor taxonomy

Map certified sensors onto Factora SENSOR_TYPES. Do not name a hardware brand in the registry.

Introduction

What this covers

How to map a vendor SKU onto Factora registry types, grouped the way a plant talks about the floor.

Why it matters on the floor

A location badge registered as vibration, or a water meter stored as kilowatt-hours, trains the wrong alert and the wrong energy total.

By the end you can

  • Place a sensor in the right group, from room climate through safety and environment
  • Use the hardware table for long-range sensors, carrier-grade LoRaWAN, industrial gateways, and location tags without swapping their jobs
  • Keep anonymous presence, water volume, and electrical current on their own types

About 25 minutes. Prerequisites: Protocol map, so you know the value still arrives as MQTT or HTTP after the vendor decode.

Sensor taxonomy

The registry types in code are the commercial language. Certified sensors must map onto them. The vendor is chosen at the survey.

Sensor registry for Demo Food Plant, with device codes, types, and whether each sensor is reporting.
Map the vendor SKU onto one of these types. Ingest tokens are not listed on this screen.

Groups (plant language)

  • Climate and room: temperature, humidity, CO2, VOC, PM2.5, dew point, illuminance, noise
  • Thermal process: process/core/surface/jacket/exhaust temperature
  • Pressure, vacuum, flow: bar, kPa, Pa, L/min, steam kg/h
  • Level: tank %, metres, interface
  • Wet chemistry: pH, conductivity, turbidity, DO, chlorine
  • Product quality: moisture, Brix, density, particles
  • Rotating equipment: vibration mm/s, rpm, runtime hours
  • Electrical and energy: kW, A, V, power factor (water m³ is utilities, not kWh)
  • Mass and count: kg, pcs, line speed, reject %
  • Safety: door binary, leak, O2, LEL, CO, occupancy (anonymous)
  • Environment: stack/emissions proxies as configured

Typical path, not a brand

Factora typeUsual path
temperature / humidityCertified room or process transmitter
co2 / IAQIndoor air sensor
tank_levelUltrasonic or pressure level, often Modbus or 4–20 mA
vibrationTransmitter on the machine, Modbus or analog
energy / currentMeter via Modbus or pulse
door / leakDigital input on the industrial gateway
occupancyAnonymous presence count, not a named person
people or tool locationRTLS tags, separate from process sensors

Do not register a location tag as vibration.

Create a free account or log in to save this lesson on your progress.

Check understanding

Progress is stored in this browser until you log in. Passing is 70%.

1. Water volume m³ should be stored as
2. Anonymous occupancy is