Knowledge Hub

Factora Academy

Knowledge Hub · Courses · FactoraERP · System Integrators · 12 min

Cut-over

Professional · Data Migration and Advanced Configuration · Step 2: Loading and validating · badge Migration Specialist

Introduction

What this covers

How to freeze the old system, load the final deltas, reconcile again, open FactoraERP, and leave the old system read-only.

Why it matters on the floor

If the old system stays editable, people will receive a truck in both places. Read-only is what makes the new lot the only lot.

By the end you can

  • Freeze the old system, then load only the deltas since the trial
  • Reconcile totals again before users are told to start
  • Leave the old system read-only for reference

About 12 minutes. Prerequisites: Trial loads.

Professional · Data Migration and Advanced Configuration Module: Step 2: Loading and validating

Cut-over

Freeze the old system, load final deltas, reconcile, then open the new system. Keep the old one read-only for reference.

Learning objectives

  • Freeze the old system, then load only the deltas since the trial
  • Reconcile totals again before users are told to start
  • Leave the old system read-only for reference

Walk the screen

  1. Agree the freeze time. After that time the legacy sheet or system takes no new trucks, orders, or stock moves.
  2. Collect the deltas: records created after the trial extract.
  3. Load those deltas into the workspace that will go live, using the same template.
  4. Reconcile the same totals as the trial: supplier counts, stock quantities, open orders if they were in scope.
  5. Tell users the new workspace is the place to log the next truck. Give them their own roles, not the migration account.
  6. Set the old system to read-only. Keep it for lookup. Do not keep entering deliveries there.

Worked example

Freeze is Friday 16:00. Two trucks arrived after the trial extract. They are the delta. After load, Warehouse matches the legacy quantity including those two nets. On Monday the gate uses Material Intake. The old sheet is read-only and is not updated.

Common mistakes

  • Leaving the old sheet editable 'for a few days'.
  • Skipping the second reconcile because the trial matched last week.
  • Letting the migration account be the login the gate uses.

Recap

  • Freeze, load deltas, reconcile, then open the new system.
  • The old system stays read-only.
  • The reconcile is repeated at cut-over, not only at trial.

Badge

Completing this level is the badge Migration Specialist.

Badge on completion: Migration Specialist

Quiz for this module: Step 2: Loading and validating.

Create a free account or log in to save this lesson on your progress.

Check understanding

Progress is stored in this browser until you log in. Passing is 70%.

1. Where should trial loads happen?
2. Totals should be reconciled against the legacy system.
3. After the freeze, the old system should be
4. A quantity mismatch at trial should be fixed by hand so the total looks right.