Troubleshooting

401, wrong topic, paused tenant, 429, unit mismatch.

Introduction

What this covers

A symptom table for the ingest, login, OEE, unit, and access errors you will actually see after go-live.

Why it matters on the floor

Treating a missing OEE figure as a broken percentage, or a logo redirect as an academy outage, sends the night shift down the wrong fix.

By the end you can

  • Match an unauthorized HTTP response, a silent MQTT session, duplicate counts, and a rate-limit response to the specific check
  • Read a missing OEE figure as missing run or counter evidence in the window
  • Separate a wrong unit mapping, and an ops viewer who cannot create a factory, from a fault in the academy itself

About 14 minutes. Prerequisites: The ingest lab and the energy and counter mapping lesson, so each check refers to a step you have already done.

Troubleshooting

SymptomCheck
HTTP 401Token, paused factory, missing Bearer
MQTT silentUsername=code, password=token, exact topic, firewall 1883
Duplicate countsEmpty messageId on retries
429Login 8/10 min; ingest 180/min
OEE N/ANo overlapping run and no counters in window — not a “broken %”
Wrong unitskW mapped as kWh; a vendor object not split into a number
Ops 403 on createViewer role
Logo 307 on academyUnrelated; academy host must stay public

Walk the screen

Discovered devices waiting to be claimed into the registry.
Claim a discovered device into this factory. This list is not a second registry, and it is not a token page.
  1. HTTP 401: check the token, whether the factory is paused, and that the request is a bearer request.
  2. MQTT silence: check the device code as username, the token as the secret, the exact topic, and the firewall for port 1883.
  3. Duplicate counts: look for an empty message id on retries.
  4. 429: login is limited to 8 in 10 minutes. Ingest is limited to 180 a minute.
  5. OEE N/A: look for a missing overlapping run or missing counters. It is not a broken percentage.
  6. Wrong units or an ops viewer who cannot create a factory are configuration, not an academy outage. A logo redirect is unrelated.

Worked example

OEE shows N/A on the demo line. You find no run overlapping the window and you do not 'fix' it to 100 percent. Separately, a device that announced itself on Discovered devices is claimed from there. It is not typed again as a second registry.

Common mistakes

  • Treating OEE N/A as a math bug.
  • Calling the academy broken because a logo redirected.
  • Retrying without a message id and then deleting rows to hide the double count.

Recap

  • Match the symptom to the check in the table.
  • 429 and 401 are limits and credentials, not OEE.
  • Discovered devices are claimed into the registry you already have.

Create a free account or log in to save this lesson on your progress.

Check understanding

Progress is stored in this browser until you log in. Passing is 70%.

1. Too many plant login posts return
2. OEE N/A usually means
3. An empty message id on a retry can duplicate counts.
4. An ops viewer who cannot create a factory should be told